APC SurgeArrest Recall (2013)

From OldSurge.com
Revision as of 01:40, 12 September 2026 by Power (talk | contribs) (Created page with "= APC SurgeArrest Recall (2013) = The APC SurgeArrest Recall was announced in 2013 and affected approximately 15 million APC 7-Series and 8-Series surge protectors manufactured between 1993 and 2002. The affected products were sold under the APC SurgeArrest Personal, Professional, Performance, and Network product lines. == Hazard == According to APC and the U.S. Consumer Product Safety Commission (CPSC), affected surge protectors could overheat, smoke, melt, and pose...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

APC SurgeArrest Recall (2013)

The APC SurgeArrest Recall was announced in 2013 and affected approximately 15 million APC 7-Series and 8-Series surge protectors manufactured between 1993 and 2002.

The affected products were sold under the APC SurgeArrest Personal, Professional, Performance, and Network product lines.

Hazard

According to APC and the U.S. Consumer Product Safety Commission (CPSC), affected surge protectors could overheat, smoke, melt, and pose a fire hazard.

Affected Models

Affected 7-Series models included:

  • PRO7
  • PRO7C
  • PRO7T
  • PER7
  • PRF7

Affected 8-Series models included:

  • PRO8
  • PRO8T2
  • PER8T
  • NET8

Additional affected models were included in the recall.

Identification

Affected units can be identified by the serial number located on the underside of the surge protector.

The two digits immediately following the first letter or letters of the serial number indicate the year of manufacture.

Units with the following year codes were included in the recall:

Year Code Included in Recall
93 Yes
94 Yes
95 Yes
96 Yes
97 Yes
98 Yes
99 Yes
00 Yes
01 Yes
02 Yes

OldSurge Archive Specimens

Model Serial Number Year Country Recall Status
PRO7 Z94030204087 1994 China Recalled
PRO7 Z98010201706 1998 China Recalled
PRO7 Z99080215662 1999 China Recalled
PRO7 Z20250P17876 2002 China Recalled
PRO7 4Z0608P02342 2006 Philippines Not Recalled
PRO7 7Z1714L05335 2017 Philippines Not Recalled

References

  • APC by Schneider Electric recall notice
  • U.S. Consumer Product Safety Commission recall notice