Universal 71641 (Yellowed Example): Difference between revisions

From OldSurge.com
Jump to navigation Jump to search
PowerPig (talk | contribs)
PowerPig (talk | contribs)
No edit summary
Line 36: Line 36:
* Flame Rating: VW-1
* Flame Rating: VW-1
* UL File Number (Cord): E176194
* UL File Number (Cord): E176194
* Power Cord Type: SJT
* Conductors: 16 AWG × 3
* CSA File Number: LL109777
* Cord Manufacturer: Apollo


== Mounting Provisions ==
== Mounting Provisions ==
Line 72: Line 76:


The cord-entry end incorporates an unused circular knockout molded into the enclosure. The feature appears designed to accommodate a resettable circuit breaker or similar component, although it is not populated on the documented example. Protection appears to be integrated into the switch and surge-suppression assembly.
The cord-entry end incorporates an unused circular knockout molded into the enclosure. The feature appears designed to accommodate a resettable circuit breaker or similar component, although it is not populated on the documented example. Protection appears to be integrated into the switch and surge-suppression assembly.
== Testing ==
The documented example was tested for basic electrical operation and wiring integrity.
Testing with a receptacle tester confirmed correct hot, neutral, and ground wiring. No open ground, open neutral, reversed polarity, or other wiring faults were detected.
The rocker switch successfully controlled power to all outlets.
When energized, the red SURGE indicator illuminated, indicating that surge-protection circuitry remained active.
<gallery mode="packed" heights="250">
File:surge_universal_71641_yellowed_testing_lightoff_01.jpg|71641 connected to power with the rocker switch in the OFF position.
File:surge_universal_71641_yellowed_testing_lighton_01.jpg|SURGE indicator illuminated during testing.
File:surge_universal_71641_yellowed_testing_polaritygrounding_01.jpg|Outlet tester indicating correct wiring and grounding.
</gallery>
== Teardown ==
The Universal 71641 enclosure is secured using multiple Phillips-head screws and can be opened non-destructively.
The 71641 continues Universal's use of stamped brass bus bars for power distribution but incorporates a larger and more sophisticated surge-suppression assembly than earlier Universal products documented by the archive.
The transformer-spaced outlet remains mechanically integrated into the same bus-bar system as the remaining outlets.
The documented example exhibited typical dust accumulation and debris consistent with long-term service but showed no obvious evidence of overheating, melted components, or catastrophic electrical failure.
<gallery mode="packed" heights="250">
File:surge_universal_71641_yellowed_teardown_open_01.jpg|71641 opened following removal of the enclosure screws.
</gallery>


== Product Gallery ==
== Product Gallery ==
Line 94: Line 129:
File:surge_universal_71641_yellowed_plug_detail_01.jpg|Grounding plug with molded approval markings.
File:surge_universal_71641_yellowed_plug_detail_01.jpg|Grounding plug with molded approval markings.
File:surge_universal_71641_yellowed_corddetail_01.jpg|Power cord specifications and approval markings.
File:surge_universal_71641_yellowed_corddetail_01.jpg|Power cord specifications and approval markings.
File:surge_universal_71641_yellowed_cable_detail_02.jpg|Additional power cord specifications and manufacturer markings.
File:surge_universal_71641_yellowed_plug_01.jpg|Grounded attachment plug and power cord.
File:surge_universal_71641_yellowed_plug_01.jpg|Grounded attachment plug and power cord.
</gallery>
</gallery>
== Condition Upon Acquisition ==
The documented example was acquired as part of a collection of surplus electrical equipment and exhibited significant yellowing, accumulated dirt, and cosmetic wear consistent with long-term use and storage.
The unit was cleaned prior to detailed documentation and photography.
[[File:surge_universal_71641_yellowed_beforecleaning_01.jpg|center|600px|71641 as acquired before cleaning.]]

Revision as of 15:22, 21 September 2026

Universal 71641 (Yellowed Example)

Overall view of the yellowed Universal 71641.

Overview

The Universal 71641 is a six-outlet surge protector manufactured in 2004 and marketed for home and office electronic equipment.

The documented example exhibits significant enclosure yellowing and serves as an interesting example of long-term plastic aging.

Specifications

  • Manufacturer: Universal
  • Model: 71641
  • Manufacturing Date: May 23, 2004
  • Outlets: 6 grounded outlets
  • Transformer-spaced outlet: Yes
  • Power Switch: Illuminated RESET/OFF rocker switch
  • Surge Indicator: Yes
  • Length: Approximately 10.5 in (26.7 cm)
  • Width: Approximately 1.31 in (3.3 cm)
  • Height:
    • Approximately 1.31 in (3.3 cm) at the outlet section
    • Approximately 1.63 in (4.1 cm) at the control section
  • Transformer-Spaced Outlet: Yes
  • Manufacturing Date: May 23, 2004
  • Voltage Rating: 125 VAC
  • Current Rating: 15 A
  • Frequency: 60 Hz
  • Maximum Load: 1875 W
  • Suppressed Voltage Rating: 330 V
  • Country of Manufacture: China
  • Power Cord Length: Approximately 6 ft (1.8 m)
  • Power Cord Type: SJT
  • Conductors: 16 AWG × 3
  • Flame Rating: VW-1
  • UL File Number (Cord): E176194
  • Power Cord Type: SJT
  • Conductors: 16 AWG × 3
  • CSA File Number: LL109777
  • Cord Manufacturer: Apollo

Mounting Provisions

The underside incorporates two keyhole-style mounting slots.

The mounting arrangement supports three practical installation orientations:

  • Horizontal mounting
  • Vertical mounting with the cord entry positioned upward
  • Vertical mounting with the cord entry positioned downward

This provides greater installation flexibility than many previously documented surge protectors in the archive.

Physical Description

The Universal 71641 utilizes a beige plastic enclosure with six grounded outlets arranged in a single row.

The outlet nearest the end of the strip is spaced farther from the adjacent receptacle to accommodate transformer-style power adapters and oversized plugs.

A rocker-style RESET/OFF power switch and surge-protection indicator are located near the power-cord entry point.

The documented example exhibits substantial yellowing of the enclosure. Areas immediately surrounding two outlet positions have retained noticeably lighter coloration, suggesting that two-prong devices may have remained plugged into the unit for extended periods of time. The protected areas appear to have been shielded from the environmental factors responsible for the surrounding discoloration.

The yellowing pattern appears consistent with prolonged use of multiple two-prong devices, which shielded portions of the enclosure from the aging processes affecting the surrounding plastic.

The outlet nearest the rounded end of the enclosure is physically separated from the remaining outlets and specifically labeled "TRANSFORMER." The additional spacing provides clearance for oversized power adapters and wall-wart style transformers.

The cord-entry end incorporates an unused circular knockout molded into the enclosure. The feature appears to be intended for installation of a circuit breaker or related component, although it is not populated on the documented example. Protection appears to be integrated into the switch and surge-suppression assembly.

The 71641 utilizes a low-profile enclosure with a raised control section near the power-cord entry point. The housing design is broadly similar to earlier Universal models but incorporates a dedicated transformer-spaced outlet and a slightly more refined profile.

The documented example exhibits significant yellowing across most exposed surfaces. Areas shielded by long-term plug insertion have retained a noticeably lighter coloration, creating a visible contrast with the surrounding plastic.

The final outlet is physically separated from the remaining receptacles and is specifically labeled "TRANSFORMER." The additional clearance is intended to accommodate oversized power adapters and wall-wart style transformers.

The cord-entry end incorporates an unused circular knockout molded into the enclosure. The feature appears designed to accommodate a resettable circuit breaker or similar component, although it is not populated on the documented example. Protection appears to be integrated into the switch and surge-suppression assembly.

Testing

The documented example was tested for basic electrical operation and wiring integrity.

Testing with a receptacle tester confirmed correct hot, neutral, and ground wiring. No open ground, open neutral, reversed polarity, or other wiring faults were detected.

The rocker switch successfully controlled power to all outlets.

When energized, the red SURGE indicator illuminated, indicating that surge-protection circuitry remained active.


Teardown

The Universal 71641 enclosure is secured using multiple Phillips-head screws and can be opened non-destructively.

The 71641 continues Universal's use of stamped brass bus bars for power distribution but incorporates a larger and more sophisticated surge-suppression assembly than earlier Universal products documented by the archive.

The transformer-spaced outlet remains mechanically integrated into the same bus-bar system as the remaining outlets.

The documented example exhibited typical dust accumulation and debris consistent with long-term service but showed no obvious evidence of overheating, melted components, or catastrophic electrical failure.

Condition Upon Acquisition

The documented example was acquired as part of a collection of surplus electrical equipment and exhibited significant yellowing, accumulated dirt, and cosmetic wear consistent with long-term use and storage.

The unit was cleaned prior to detailed documentation and photography.

71641 as acquired before cleaning.
71641 as acquired before cleaning.